1-5
GEN
INFO
General information
How to use this manual
Manual format
The format of this manual has been designed to make service procedures clear and easy to under-
stand. Use the information below as a guide for effective and quality service.
• Parts are shown and detailed in an exploded diagram and are listed in the component list (see
1
in the following figure for an example page).
• The component list consists of part names and quantities, as well as bolt and screw dimensions
(see
2
in the following figure). To assemble or install the components, reverse the steps indicated
in the component list.
• Symbols are used to indicate important aspects of a procedure, such as the grade of lubricant and
the lubrication point (see
3
in the following figure).
• Tightening torque specifications are provided in the exploded diagrams (see
4
in the following fig-
ure), and in the related detailed instructions. Some torque specifications are listed in stages as
torque figures or angles in degrees.
• Separate procedures and illustrations are used to explain the details of removal, checking, and
installation where necessary (see
5
in the following figure for an example page).
TIP:
For troubleshooting procedures, see Chapter 9, “Troubleshooting.”
6-6
Impeller duct and drive shaft
*: EPNOC grease AP #0
No.
Part name
Q’ty
Remarks
1
Bolt
3
M6 20 mm
2
Cap
1
3
O-ring
1
Not reusable
4
Cap
1
5
Impeller
1
6
Drive shaft
1
7
Oil seal
1
Not reusable
8
Oil seal
1
Not reusable
9
Rear bearing
1
Not reusable
10
Spacer
1
11
Front bearing
1
Not reusable
12
Impeller duct
1
Jet thrust nozzle, impeller duct, and impeller housing / Impeller duct and drive shaft
6-7
JET
PUMP
Jet pump unit
Drive shaft removal
1.
Remove the impeller.
TIP:
Hold the impeller duct assy. in a vise
between two aluminum plates
a
.
2.
Remove the drive shaft
1
.
TIP:
Remove the drive shaft using a press.
3.
Remove the rear bearing.
4.
Remove the oil seals.
TIP:
Remove the oil seals using a flat head screw-
driver.
5.
Remove the front bearing.
TIP:
Remove the front bearing using a press.
Impeller check
1.
Check the impeller. Replace if damaged.
Crankshaft holder 20: 90890-06552
a
a
1
Stopper guide plate: 90890-06501
Bearing puller assembly: 90890-06535
Stopper guide stand: 90890-06538
Driver rod L3: 90890-06652
Needle bearing attachment: 90890-06614
1
5
3
2
4
Summary of Contents for WaveRunner VX 700
Page 1: ...SERVICE MANUAL WaveRunner F2V 28197 ZN 11 VX 700 VX 700 F2V ...
Page 4: ......
Page 16: ...1 11 GEN INFO General information MEMO ...
Page 36: ...2 19 SPEC Specification MEMO ...
Page 104: ...5 35 POWR Power unit MEMO ...
Page 177: ...1 2 3 4 5 6 7 8 9 A Appendix Wiring diagram A 1 ...
Page 179: ......