Thermo sensor
1. Measure:
•
Thermo sensor input voltage
Out of specification
→
Check the wiring
harness.
Measurement steps:
1. Disconnect the thermo sensor coupler
1
.
2. Push the unlock button, and then measure
the input voltage at the thermo sensor cou-
pler terminals (wiring harness end).
Thermo sensor input voltage
(reference data):
Black/blue (B/L)
–
Black/orange (B/O)
4.75
–
5.25 V
1
B/O
B/L
2. Measure:
•
Thermo sensor resistance (at the speci-
fied temperatures)
Out of specification
→
Replace the
thermo sensor.
Measurement steps:
1. Remove the thermo sensor.
Refer to
“
”
in Chapter
5.
2. Suspend the thermo sensor in a container
filled with water.
3. Slowly heat the water.
4. Measure the resistance when the specified
temperatures are reached.
Thermo sensor resistance (reference
data):
Black (B)
–
Black (B)
0
°
C (32
°
F): 24.0
–
37.1 k
Ω
100
°
C (212
°
F): 0.87
–
1.18 k
Ω
B
B
Summary of Contents for WaveRunner FX Cruiser SHO
Page 1: ...SERVICE MANUAL FX SHO WaveRunner F1W 28197 1K 11 FX Cruiser SHO LIT 18616 03 12 LIT186160312 ...
Page 58: ...1 53 E GEN INFO MEMO Technical tips ...
Page 82: ...2 23 E SPEC MEMO Cable and hose routing ...
Page 110: ...3 27 E CHK ADJ MEMO General ...
Page 243: ...5 118 E POWR 1 2 3 4 5 6 7 8 9 MEMO Cooling water ...
Page 275: ...6 30 E JET PUMP 1 2 3 4 5 6 7 8 9 MEMO Intermediate housing ...
Page 353: ...E ELEC 1 2 3 4 5 6 7 8 9 7 76 MEMO Indication system ...
Page 410: ...8 55 E HULL HOOD MEMO Deck and hull ...
Page 429: ...9 18 E TRBL ANLS 1 2 3 4 5 6 7 8 9 MEMO Engine unit trouble analysis ...
Page 431: ......
Page 432: ...YAMAHA MOTOR CORPORATION USA Printed in USA Jan 2008 0 0 1 CR E ...