140
CHAPTER2 PROFIBUS Unit
;
Auto_Baud_supp = 1
; Supported
;
9.6_supp
= 1
; 9.6kbps
19.2_supp
= 1
; 19.2kbps
93.75_supp
= 1
; 93.75kbps
187.5_supp
= 1
; 187.5kbps
500_supp
= 1
; 500kbps
1.5M_supp
= 1
; 1.5Mbps
3M_supp
= 1
; 3Mbps
6M_supp
= 1
; 6Mbps
12M_supp
= 1
; 12Mbps
; Max. response times:
MaxTsdr_9.6
= 15
;
MaxTsdr_19.2
= 15
;
MaxTsdr_93.75
= 15
;
MaxTsdr_187.5
= 15
;
MaxTsdr_500
= 15
;
MaxTsdr_1.5M
= 25
;
MaxTsdr_3M
= 50
;
MaxTsdr_6M
= 100
;
MaxTsdr_12M
= 200
;
;
Min_Slave_Intervall = 1
; 100usec
;
;
;---------------------------------------------------------------------------------------------------------------------
;
Set_Slave_Add_supp = 0
; Not Supported
Freeze_Mode_supp = 0
; Not Supported
Sync_Mode_supp = 0
; Not Supported
Fail_Safe
= 0
; Not Supported
;
Modular_Station
= 1
; Modular station
Max_Module
= 1
; Max Module
;
Max_Input_Len
= 24
; Maximum of input bytes
Max_Output_Len = 24
; Maximum of output bytes
Max_Data_Len
= 48
; Maximum of data bytes
;
Max_Diag_Data_Len = 6
; Maximum diagnostic length
;
;
;---------------------------------------------------------------------------------------------------------------------
;
Module = "DI DO 8byte/Remort 8word" 0xB7,0xF7
;
EndModule
;
;
;
;=====================================================================