81
CHAPTER2 PROFIBUS Unit
(15) General-purpose output or
memory output status change .............................................. Code 010F
ON/OFF control of the general-purpose output or memory output is performed.
Command option
QWn+22
QWn+20
QWn+18
QWn+16
QWn+14 QWn+12
Output status
DO/MO/SO
number
Command response
IWm+22
IWm+20
IWm+18
IWm+16
IWm+14 IWm+12
(Details)
DO/MO/SOnumber:
One is specified among the general-purpose output 0 to 12 (13
points)*, serial general-purpose output 200 to 231 (32 points) or
memory output 100 to 131 (32 points).
Output status:
1 means ON, and 0 means OFF.
(Example)
Transmission example 1:
The serial general-purpose output 203 is turned ON.
QWn+22 QWn+20 QWn+18 QWn+16 QWn+14 QWn+12 QWn+10
QWn+8
0000
0000
0000
0000
0001
00CB
0000
010F
Response example 1:
It is normally ended.
IWm+22
IWm+20
IWm+18
IWm+16
IWm+14 IWm+12 IWm+10
IWm+8
0000
0000
0000
0000
0000
0000
0000
0200
* 0 to 4 (5 points) for the SRCP/SRCD series controllers