123
CHAPTER2 PROFIBUS Unit
2-12-5 Remote command details (utilities)
(1) Execution program number switching ................................. Code 0301
The execution program number is switched. If the program reset is hereafter ex-
ecuted, it will return to the 1st step of the program selected here.
When this command is issued, the program reset will be applied.
Command option
QWn+22
QWn+20
QWn+18
QWn+16
QWn+14 QWn+12
Program number
Command response
IWm+22
IWm+20
IWm+18
IWm+16
IWm+14 IWm+12
(Details)
Program number:
It is the inherent number of 0 to 99 assigned to each program.
(Example)
Transmission example 1:
The program is switched to NO31.
QWn+22 QWn+20 QWn+18 QWn+16 QWn+14 QWn+12 QWn+10
QWn+8
0000
0000
0000
0000
0000
001F
0000
0301
Response example 1:
It is normally ended.
IWm+22
IWm+20
IWm+18
IWm+16
IWm+14 IWm+12 IWm+10
IWm+8
0000
0000
0000
0000
0000
0000
0000
0200