105
CHAPTER2 PROFIBUS Unit
(6) ROM version number read .................................................... Code 0206
The controller system version value is read.
Command option
QWn+22
QWn+20
QWn+18
QWn+16
QWn+14 QWn+12
Command response
IWm+22
IWm+20
IWm+18
IWm+16
IWm+14 IWm+12
Version value
(Details)
Version value:
It is the system version which is possessed by the controller. If the
version is V13.30, 1330 (=532 (hexadecimal)) is indicated.
(Example)
Transmission example 1:
The controller system version is read.
QWn+22 QWn+20 QWn+18 QWn+16 QWn+14 QWn+12 QWn+10
QWn+8
0000
0000
0000
0000
0000
0000
0000
0206
Response example 1:
The version is V13.30.
IWm+22
IWm+20
IWm+18
IWm+16
IWm+14 IWm+12 IWm+10
IWm+8
0000
0000
0000
0000
0000
0532
0000
0200
M E M O
M E M O
The controller versions are as follows.
ERCX/SRCX
:V13.xx
DRCX
:V18.xx
SRCP
:V24.xx
SRCD
:V24.xxB
SRCP30
:V24.xxH