CHAPTER2 PROFIBUS Unit
10) Press
F1
(SI01) to display the Qn+3.7
to Qn.0 and Im+3.7 to Im.0 status. Press
F2
(SI02) to display the Qn+7.7 to
Qn+4.0 and Im+7.7 to Im+4.0. Press
F3
(WIO) to display the status of the remote
register.
SI
00000000 00000000
00000000 00000000
SO
00000000 00000000
00000000 00000000
WI
00000000 00000000
FFFF1000 00000000
WO
00000000 00000000
00000000 00000000
11) Continue displaying the status of each se-
rial I/O.
If
F1
(SI01) was pressed above in step
10), then the Qn+1.7 to Qn.0, Qn+3.7 to
Qn+2.0, Im+1.7 to Im.0 and Im+3.7 to
Im+2. status is displayed from the upper
row.
If
F2
(SI02) was pressed above in step
10), then the Qn+5.7 to Qn+4.0, Qn+7.7
to Qn+6.0, Im+5.7 to Im+4.0 and Im+7.7
to Im+6. status is displayed from the up-
per row.
[OPRT-STEP] 100 0: 0
001:MOVA 254,100
[ 0.00, 0.00]
1SI012SI023WIO
[OPRT-STEP] 100 0: 0
001:MOVA 254,100
[ 0.00, 0.00]
1SI012SI023WIO
12) This is the screen when
F3
(WI0) is
pressed.
Each remote register will be displayed in
the hexadecimal mode.
(Each register is indicated with 4 charac-
ters.)
The top row displays the statuses of
QWn+14, QWn+12, QWn+10 and
QWn+8 from the left.
The 2nd row indicates the statuses of
QWn+22, QWn+20, QWn+18 and
QWn+16 from the left.
The 3rd row indicates the statuses of
IWm+14, IWm+12, IWm+10 and
IWm+8 from the left.
The bottom row indicates the statuses of
IWm+22, IWm+20, IWm+18 and
IWm+16 from the left.
13) Press the
ESC
key to return to the screen
in step 10).