Reference Manual
Reference
121
Master Job
The Master Job mode features convenient data initialization and archiving tools. To enter the Master Job mode, press
the [JOB] button in the Master mode. Press the [EXIT] button to return to the original display.
This function lets you send all your edited parameter settings for the currently selected Master to a computer or another
MIDI device for data archiving.
Press the [ENTER] button to execute the Bulk Dump.
NOTE:
In order to execute Bulk Dump, you will need to set the correct MIDI Device Number (
). When a bulk message is
transmitted from the S90 XS/S70 XS with the Device number is set to “all,” the S90 XS/S70 XS is recognized as Device Number
1; when the Device number is set to “off,” the S90 XS/S70 XS does not transmit the bulk message.
NOTE:
You can also send the Bulk Dump from the Keyboard, by holding down the [SHIFT] button and pressing the [MASTER] button.
This function lets you reset (initialize) all Master parameters to their default
settings. It also allows you to selectively initialize certain parameters, such
as Common settings and Zone settings.
1
All (All Parameters)
Determines whether or not all settings for the selected Master are initialized. When
set to “on,” other parameters in this display cannot be set.
Settings:
on (transmitted), off
2
Common
Determines whether or not all Common parameter settings for the selected Master are initialized. When set to “on,” executing the Job
initializes all the parameter settings of Common Edit.
Settings:
on (transmitted), off
3
Zone
Determines whether or not all Zone parameter settings for the selected Master are initialized. When set to “on,” executing the Job
initializes all the parameter settings of Zone Edit. You can select the settings after an initialize operation via
4
Init Type.
When this parameter is set to off, the parameter (
4
–
7
) are not available.
Settings:
on (transmitted), off
4
Init Type (Initialize Type)
Determines how the Zone parameter settings for the selected Master are initialized. Three methods of Initializing are available. If you want
to determine other settings, initialize via the nearest type, then edit the Zone Edit parameters.
Settings:
split, zone, layer
split
Sets the Zone 1 and Zone 2 to on, then splits the keyboard range using Zone 1 and Zone 2. “Upper Ch” determines the MIDI
transmit channel of the upper range of the keyboard, “Lower Ch” determines the MIDI transmit channel of the lower range of the
keyboard, and “Split Point” determines the note (C -2 – G8) number which separates the upper range and lower range of the
keyboard. .
zone
See below.
Operation
[MASTER]
Select Master programs
[Job]
Master Job Select display
Bulk (Bulk Dump)
Initialize
zone
Tx Ch
Int Sw
Ext Sw
Note Low
Note High
1
1
on
on
C -2
B0
2
2
on
on
C1
B2
3
3
on
on
C3
B4
4
4
on
on
C5
G8