2
The P
attern Mode
14. Pattern & Phrase Editing — The Pattern Jobs
RS7000
137
4
Rate
[Settings] 000% ~ 200%,
***
Specifies the percentage by which the target notes will be
shifted from their original velocities.
Settings below 100% reduce the velocities, and settings
above 100% increase the velocities proportionately. When
the Set All parameter is not “OFF” this parameter appears as
“
***
” and cannot be changed.
5
Offset
[Settings] -127 ~ +127,
***
Adds a fixed value to the Rate-adjusted velocity values.
A setting of 0 produces no change. Settings below 0 reduce
the velocities, and settings above 0 increase the velocities.
When the Set All parameter is not “OFF” this parameter
appears as “
***
” and cannot be changed.
This job alters the gate times of the specified range of notes.
Gate time changes are calculated as follows:
Adjusted gate time =
(original gate time
×
Rate) + Offset
If the result is 0 or less, the value is set to 1.
1
Phrase
[Settings] 001 ~ 256
2
Range
[Settings] Measure:Beat:Clock
001:1:000 ~ 257:1:000
Sets the range of measures/beats/clocks over which the job is
applied.
3
Set All
[Settings] Off (0), 0001 ~ 9999
Sets the gate times of all target notes to the same fixed value.
When set to “OFF” the Set All parameter has no effect.
When set to a value other than “OFF” the Rate and Offset
parameters are unavailable and appear as “
***
” on the dis-
play.
4
Rate
[Settings] 000% ~ 200%,
***
Specifies the percentage by which the gate time of the target
notes will be changed.
Settings below 100% shorten the notes, and settings above
100% lengthen the notes proportionately. When the Set All
parameter is not “OFF” this parameter appears as “
***
” and
cannot be changed.
5
Offset
[Settings] -9999 ~ +9999,
****
Adds a fixed value to the Rate-adjusted gate time values.
A setting of 0 produces no change. Settings below 0 shorten
the gate time, and settings above 0 lengthen the gate time.
When the Set All parameter is not “OFF” this parameter
appears as “
****
” and cannot be changed.
03 Modify Gate Time
(Vel)
(Vel)
(Vel)
96
64
48
32
48
32
24
16
127
96
72
48
Original velocity
Rate = 50%
Rate = 150%
(Vel)
(Vel)
(Vel)
96
64
48
32
76
44
28
12
116
84
68
52
Original velocity
Rate = -20
Rate = +20
3
1
2
5
4
[Knob 2]
[Knob 3]
[F4]
(Gate)
(Gate)
(Gate)
32
32
32
48
16
16
16
24
48
48
48
72
Original gate time
Gate time rate = 50%
Gate time rate = 150%
(Gate)
(Gate)
(Gate)
32
32
32
48
12
12
12
28
52
52
52
68
Original gate time
Offset = -20
Offset = +20
Summary of Contents for RS7000 Ver.1.2
Page 1: ......
Page 26: ...Restoring the Initial Factory Settings 26 RS7000 ...
Page 50: ...6 Finalizing Your Sound 50 RS7000 ...
Page 178: ...7 Pattern Chain Editing 178 RS7000 ...
Page 254: ...4 The Sample Jobs 254 RS7000 ...