ACD1
66
b) Writing component
1.
Connection to PC
Connect the LAN terminal of the PC and the NETWORK terminal of the ACD1 with a LAN straight cable.
2.
Activating the ACD1
Turn on the power while holding down the following three keys on the ACD1 panel for
fi
ve seconds or more. (IP static mode)
[
▲
INC/YES] + [
▼
DEC/NO] + [NEXT]
The following screen will be shown on the LCD of the ACD1 when the IP static mode is started.
YAMAHA ACD1
000:
[Example of the ACD1 LCD display]
3.
Activating the software for writing component
Double click on the icon “sync2.exe” of C:¥ACD1¥Tool¥sync¥.
4.
Check of setup
Check the following items.
Check if the [Con
fi
guration
fi
le:] is set as follows. (Refer to “Setup/execution screen”)
C:¥ACD1¥Data¥ACD1_cpt_list.dat
[Setup/execution screen]
Component data writing will follow if all the parameters are correct.
5.
Writing component data
Click on the [Execute] button.
Writing of only the necessary
fi
les will be conducted.
The writing is
fi
nished when [Update was completed.] is displayed. (Refer to “Example of Writing Completion Screen”)
6.
After writing component data
Restarting will not take place automatically after writing component data unlike boot/program updating. Turn off the power
manually and then restart if you want to start in the normal mode.