SPECIFICATIONS
Scene Memory
50 scenes per ampli
fi
er
Number of ampli
fi
ers
that can be connected
Via the DATA PORT connector
Up to 32 units
Via the MONITOR/REMOTE connector Up to 8 units
Display
16 characters × 2 lines backlit LCD
Power Requirements
100 V, 50 Hz/60 Hz
Power Consumption
15 W
Dimensions (W × H × D)
480 × 44 × 362 mm
Weight
4.0 kg
Operating temperature range
0 °C – 40 °C
Storage temperature range
-20 °C – 60 °C
AC Cable Length
250 cm
Accessories
AC power cord, Euroblock plug (16P), Owner’s Manual, Rubber feet × 4
• Control I/O
Terminal
Format
Level
Connector
MONITOR/REMOTE
*1
̶
̶
D-SUB 15P (Female) × 8
DATA PORT
*2
RS-485
RS-485
RJ-45
GPI
*3
IN
̶
0‒5 V
Euroblock (3.5 mm pitch)
OUT
̶
Open Collector
+V
̶
5 V
FAULT OUTPUT
*4
̶
̶
NETWORK
IEEE 802.3
10Base-T/100Base-TX
RJ-45
*1
Supported models
XP7000, XP5000, XP3500, XP2500, XP1000, XM4180, XM4080, XH200
Guaranteed cable length: 50 m
*2
Supported models
T5n, T4n, T3n, PC9501N, PC6501N, PC4801N, PC3301N, PC2001N, PC9500N, PC4800N, PC3300N
*3
Inputs: 4 channels, Outputs: 4 channels
Outputs: Withstanding Voltage Vmax = 12 V (OFF)
Outputs: Sink Current Imax = 75 mA/pin, Imax = 300 mA/4pins (ON)
+V: Imax =100 mA/2pins
*4
Input: Imax = 1A, Vmax = 30 VDC
• Pin Assignment
MONITOR/REMOTE
DATA PORT
1
GND
2
REMOTE CONTROL
STANDBY
3
MONITOR
MODEL ID
4
REMOTE CONTROL
MUTE CH D
5
MUTE CH C
6
MUTE CH B
7
MUTE CH A
8
MONITOR
PROTECT STATUS CH D
9
PROTECT STATUS CH C
10
PROTECT STATUS CH B
11
PROTECT STATUS CH A
12
OUTPUT LEVEL CH D
13
OUTPUT LEVEL CH C
14
OUTPUT LEVEL CH B
15
OUTPUT LEVEL CH A
1
NC
2
NC
3
NC
4
RxD/TxD -
5
RxD/TxD +
6
NC
7
GND
8
GND
5
4
3
2
1
10
9
8
7
6
15
14
13
12
11
8
1