44
ACD1
*
Inspection using a compatible amplifi er
The following tests can be conducted using an ampli
fi
er that can be connected to the ACD1.
■
When using an XP series, XM series or XH series amplifi er
MONITOR/REMOTE
terminal
XP series
XM series
XH series
VGA cable
ACD1 (REAR PANEL)
Compatible amplifier
Connect any one of the REMOTE/MONITOR terminals 32 to 39 of the ACD1 to be tested to the REMOTE/MONITOR
terminal of the compatible ampli
fi
er with a VGA cable.
• STANDBY Control Check (“2. Amp Control”
→
“Standby”)
1. Press the [NEXT] key in the Home screen and then use the [
▲
INC/YES]/[
▼
DEC/NO] key to select “Amp Control”
category.
2.AmpControl
Standby
å
2. Press the [NEXT] key to move to the sub category of the “Amp Control”.
3.
Use
the
[
▲
INC/YES]/[
▼
DEC/NO] key to select “Standby”.
2.AmpControl
Standby
å
4. Press the [NEXT] key to move to the “Amp ID”.
5.
Use
the
[
▲
INC/YES]/[
▼
DEC/NO] key to select the ID for the ampli
fi
er for checking.
(Select the number of the REMOTE/MONITOR terminal to which the VGA cable is connected.)
Amp ID:
32
Standby
å
6. Check that the POWER/STANDBY LED of the compatible ampli
fi
er lights up in red.
7. Press the [BACK] key to move to the sub category of the “Amp Control” again.