No.
Description
Alternatives
6
Optional cards
0: No optional cards
7
Internal display
1: Standard internal display installed
8
Other options
0: No other options installed
Example
.
-
-
3
4
5 6
7 8
2
1
075
A
0 0
1 0
4
HVL
.
No.
Example
Description
1
HVL
HYDROVAR
2
4
Power Supply: 3~ 380–460 VAC
3
075
Shaft power: 7.5 kW (10.0 HP)
4
A
Enclosure rate: IP 55 / Type1
5
0
Standard communication
6
0
No optional cards installed
7
1
Standard internal display installed
8
0
No other options installed
3.5 Technical Data
Electrical specification
HVL
2.015 2.022 2.030 2.040 3.015 3.022 3.030 3.040 3.055 3.075 3.110 4.015 4.022 4.030 4.040 4.055 4.075 4.110 4.150 4.185 4.220
Input
Mains Supply
L N
L1 L2 L3
L1 L2 L3
Nominal
input voltage
(Vin):
208–240±10%
208–240±10%
380–460±15%
Maximum
Input Current,
continuous
[A]:
11.6 15.1 22.3 27.6
7.0
9.1
13.3 16.5 23.5 29.6 43.9
3.9
5.3
7.2
10.1 12.8 16.9 24.2 33.3 38.1 44.7
efficiency,
rated [%],
typically:
94.0 93.5 93.5 93.5 96.0 96.0 96.0 96.0 96.0 96.0 96.0 96.0 96.5 96.5 96.5 97.0 97.0 97.0 97.0 97.0 97.0
Output
Output
voltage (V)
0–240
0–100% of supply voltage
0–100% of supply voltage
Maximum
output
current,
continuous
[A]:
7.5
10
14.3 16.7
7.5
10
14.3 16.7 24.2
31
44
4.1
5.7
7.3
10
13.5
17
24
32
38
44
Output
frequency
(Hz)
15–70
Environmental specification
Storage temperature
-30°C [-22°F] to 70°C [158°F]
Relative humidity
5%-95% - Condensation is not permitted
Operational temperature
-10°C [-14°F] to 55°C [131°F]
100% power rating -10°C [-14°F] to 40°C [104°F]
with de-rating 40°C [104°F] to 55°C [131°F]
3 Product Description
HVL 2.015-4.220 Installation, Operation, and Maintenance Manual
15