36
VC707 Evaluation Board
UG885 (v1.2) February 1, 2013
Chapter 1:
VC707 Evaluation Board Features
lists the SFP+ module RX and TX connections to the FPGA.
lists the SFP+ module control and status connections to the FPGA.
10/100/1000 Tri-Speed Ethernet PHY
[
, callout
The VC707 board utilizes the Marvell Alaska PHY device (88E1111) U50 for Ethernet
communications at 10, 100, or 1000 Mb/s. The board supports SGMII mode only. The PHY
connection to a user-provided Ethernet cable is through a Halo HFJ11-1G01E RJ-45
connector (P4) with built-in magnetics.
On power-up, or on reset, the PHY is configured to operate in SGMII mode with PHY
address
0b00111
using the settings shown in
. These settings can be overwritten
by software commands passed over the MDIO interface.
Table 1-15:
FPGA U1 to SFP+ Module Connections
FPGA (U1) Pin
Schematic Net Name
SFP+ Module (P3)
Pin
Name
AL5
SFP_RX_N
12
RD_N
AL6
SFP_RX_P
13
RD_P
AM4
SFP_TX_P
18
TD_P
AM3
SFP_TX_N
19
TD_N
AP33
SFP_TX_DISABLE_TRANS
3
TX_DISABLE
Table 1-16:
SFP+ Module Control and Status
SFP Control/Status
Signal
Board Connection
SFP_TX_FAULT
Test Point J22
High = Fault
Low = Normal Operation
SFP_TX_DISABLE
Jumper J6
Off = SFP Disabled
On = SFP Enabled
SFP_MOD_DETECT
Test Point J21
High = Module Not Present
Low = Module Present
SFP_RS0
Jumper J38
Jumper Pins 1-2 = Full RX Bandwidth
Jumper Pins 2-3 = Reduced RX Bandwidth
SFP_RS1
Jumper J39
Jumper Pins 1-2 = Full TX Bandwidth
Jumper Pins 2-3 = Reduced TX Bandwidth
SFP_LOS
Test Point J20
High = Loss of Receiver Signal
Low = Normal Operation