Exploded View & Parts List
WorkCentre Pro 412
Launch Issue
8-31
August 2001
8-13-1 FuserAss’y Parts List
No
DESCRIPTION
SEC. CODE
Q’TY
REMARK
0
ELA HOU-FUSER(110V)ASS’Y
126N00182
1
110V
ELA HOU-FUSER(220V)ASS’Y
126N00183
1
220V
1
PMO-UPPER FUSER
1
2
RMO-ROLLER HEAT
1
3
PMO-BEARING H/R-F
1
4
BEARING-H/R L
1
5
GEAR-FUSER
126N00184
1
6
MEA RACK-CLAW ASS'Y
1
6-1
SPRING-SAPERATION
4
6-2
PMO-GUIDE CLAW
4
7
1
NOT SPARED
8
IPR-PIN ROLLER EXIT
2
9
NPR-ELECTRODE GEAR
1
10
NPR-ELECTRODE M
1
11
NPR-ELECTRODE F
1
12
THERMOSTAT
130N01214
1
13
THERMISTOR-FUSER
126N00185
1
14
LAMP-HALOGEN (110V)
122N00208
1
110V
LAMP-HALOGEN(220V)
122N00209
1
220V
15
PMO-LOWER FUSER
1
16
THERMISTOR-FUSER
126N00185
1
17
BEARING-PRESSURE/R
2
18
RMO-ROLLER PRESSURE
1
19
PMO-LEVER JAM R
1
20
PMO-LEVER JAM F
1
21
PMO-GUIDE INPUT
1
22
IPR-GROUND FU
1
23
PMO-ACTUATOR EXIT
1
24
PMO-GUIDE DUPLEX
032N00353
1
25
PMO-ARM ACTUATOR
1
26
SPRING-PR(7300)
2
27
LABEL(R)-HV FUSER
1
S1
SCREW-TAPTITE
8
S2
SCREW-TAPTITE
4
Summary of Contents for WorkCentre Pro 412
Page 18: ...Introduction WorkCentre Pro 412 August 2001 1 14 Launch Issue This page intentionally blank...
Page 22: ...Precautions WorkCentre Pro 412 Launch Issue 3 2 August 2001 This page intentionally blank...
Page 99: ...Maintenance Troubleshooting WorkCentre Pro 412 Launch Issue 7 17 August 2001 No Image...
Page 100: ...Maintenance Troubleshooting WorkCentre Pro 412 Launch Issue 7 18 August 2001...
Page 101: ...Maintenance Troubleshooting WorkCentre Pro 412 Launch Issue 7 19 August 2001 All Black...
Page 103: ...Maintenance Troubleshooting WorkCentre Pro 412 Launch Issue 7 21 August 2001 Dark Image...
Page 104: ...Maintenance Troubleshooting WorkCentre Pro 412 Launch Issue 7 22 August 2001 Background...
Page 105: ...Maintenance Troubleshooting WorkCentre Pro 412 Launch Issue 7 23 August 2001 Ghost...
Page 106: ...Maintenance Troubleshooting WorkCentre Pro 412 Launch Issue 7 24 August 2001 Black Dot...
Page 107: ...Maintenance Troubleshooting WorkCentre Pro 412 Launch Issue 7 25 August 2001 Horizontal Band...
Page 108: ...Maintenance Troubleshooting WorkCentre Pro 412 Launch Issue 7 26 August 2001 Irregular Density...
Page 109: ...Maintenance Troubleshooting WorkCentre Pro 412 Launch Issue 7 27 August 2001 White Spot...
Page 111: ...Maintenance Troubleshooting WorkCentre Pro 412 Launch Issue 7 29 August 2001 Poor Fusing...
Page 115: ...Maintenance Troubleshooting WorkCentre Pro 412 Launch Issue 7 33 August 2001 Fuser Error...
Page 117: ...Maintenance Troubleshooting WorkCentre Pro 412 Launch Issue 7 35 August 2001 Paper Jam Jam 1...
Page 118: ...Maintenance Troubleshooting WorkCentre Pro 412 Launch Issue 7 36 August 2001 Engine Error...
Page 163: ...Block Diagram WorkCentre Pro 412 Launch Issue 10 1 August 2001 10 Block Diagram...
Page 164: ...Block Daigram WorkCentre Pro 412 Launch Issue 10 2 August 2001 This page intentionally blank...
Page 165: ...Connection Diagram WorkCentre Pro 412 Launch Issue 11 1 August 2001 11 Connection Diagram...
Page 181: ...Schematic Diagrams WorkCentre Pro 412 Launch Issue 12 15 August 2001 12 15 LIU Circuit Diagram...
Page 182: ...Schematic Diagrams WorkCentre Pro 412 Launch Issue 12 16 August 2001 12 16 OPE Circuit Diagram...
Page 187: ...Schematic Diagrams WorkCentre Pro 412 Launch Issue 12 21 August 2001 12 21 ADF Circuit Diagram...
Page 189: ...Schematic Diagrams WorkCentre Pro 412 Launch Issue 12 23 August 2001 12 23 PTL Circuit Diagram...