© 2002 Xantrex Technology Inc.
P/N 975-0041-01-02 Rev A 03/02
5
2.0 INSTALLATION
PRE-INSTALLATION
The GTI is only designed to work with the SW4024, SW4048 and SW5548
models that have revision 4.2 (or higher) software. Prior to installing the GTI,
ensure that you have the appropriate model, the proper level of software and the
inverter has the communication cable located within.
See Figure 2-6 for the location of this cable.
WARNING: THE CRITICAL LOADS ARE NOW
POWERED THROUGH THE GTI; THESE LOADS
WILL NOT BE POWERED IF THE SW INVERTER OR
THE GTI ARE OFF OR DISCONNECTED. IT IS
RECOMMENDED THAT AN EXTERNAL BYPASS
SWITCH/BREAKER BE INSTALLED BETWEEN THE
GRID AND THE CRITICAL LOAD-PANEL. THIS
SWITCH, WHEN ENGAGED, WILL ALLOW THE
GRID TO DIRECTLY POWER THE LOADS WHILE
THE GTI OR SW INVERTER IS OFF OR
DISCONNECTED. SEE FIGURE 2-9 FOR AN
EXAMPLE OF THIS RELAY IN A XANTREX POWER
PANEL.
Required Tools and Materials
• Wire strippers
• Phillips screw driver
• Slotted screw driver
• Torque wrench
• 3/16" Hex-Head wrench
• #6 AWG Wire
Removing the Top Cover
1. Remove the four Phillips screws and starwashers and set aside. Be sure to
put these screws and washers somewhere where they can’t get lost.
Figure 2-1
Removing the Top Cover
Remove
these
phillips
screws to
remove
top cover
Remove
these
phillips
screws to
remove
top cover
Summary of Contents for Trace SW4024
Page 1: ...Installation Guide Grid Tie Interface GTI SW Series SW4024 SW4048 SW5548...
Page 44: ...2 0 INSTALLATION 38 2002 Xantrex Technology Inc P N 975 0041 01 02 Rev A 03 02 Notes...
Page 46: ...3 0 TROUBLESHOOTING 2002 Xantrex Technology Inc P N 975 0041 01 01 Rev A 01 02 40 Notes...
Page 48: ...2002 Xantrex Technology Inc P N 975 0041 01 02 Rev A 03 02 A 2...
Page 53: ......
Page 54: ......
Page 55: ......