Communications and I/O
3 - 12
MedWeld 5000 Technical Reference Manual
M-032170
Number
Type
Name
Description
1
Output
Weld Enable
Weld Mode On
2
Output
No Fault
No Faults Exist
3
Output
No Alert
No Alerts Exist.
4
Output
Weld Fault
Indicates that a weld fault error code is set
5
Output
Weld Error Bit 1
Binary Bit for weld error code 1
6
Output
Weld Error Bit 2
Binary Bit for weld error code 2
7
Output
Weld Error Bit 4
Binary Bit for weld error code 4
8
Output
Weld Error Bit 8
Binary Bit for weld error code 8
9
Output
Weld Error Bit 16
Binary Bit for weld error code 16
10
Output
Weld Complete
Initiates a weld schedule has completed.
11
Output
Weld in Progress
Indicates that a weld is currently in progress.
12
Output
Steppers are Reset
Indicates that all steppers are reset.
13
Output
Stepper Approaching Max
Stepper has entered last step.
14
Output
End of Stepper
The last weld in the last step of the programmed
stepper was reached.
15
Output
Ready to Weld
The control is ready to begin welding.
16
Output
Tip Dress Request
The weld control is requesting a tip dress.
17
Output
Spare
Spare
18
Output
Spare
Spare
19
Output
Spare
Spare
20
Output
Spare
Spare
21
Output
Spare
Spare
22
Output
Spare
Spare
23
Output
Spare
Spare
24
Output
Spare
Spare
25
Output
Spare
Spare
26
Output
Spare
Spare
27
Output
Spare
Spare
28
Output
Spare
Spare
29
Output
Spare
Spare
30
Output
Spare
Spare
31
Output
Spare
Spare
32
Output
Spare
Spare
Summary of Contents for MedWeld 5000
Page 2: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06 M 032170...
Page 6: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06...
Page 38: ...Installing the MedWeld 5000 2 12 MedWeld 5000 Technical Reference Manual M 032170...
Page 82: ...Advanced Software Features 5 12 MedWeld 5000 Technical Reference Manual M 032170...
Page 120: ...Hardware Troubleshooting 9 10 MedWeld 5000 Technical Reference Manual M 032170...