Control and DEP-
100S cannot
communicate
(DEP and MedLAN
LEDs may be off or
blinking)
Bad connection between
weld processor and DEP-
100S.
Check connection. Verify that it is
secure.
Check for bad/faulty connector and/or
cable.
Cycle power.
If networking, no network
power supply or no external
120 VAC source connected
to the power supply.
Make sure you have a network power
supply and that external 120VAC is
connected.
Faulty DEP-100S, WTC
processor, or network
power pack.
Replace as necessary.
Incorrect network address
for weld control.
Verify the welder ID and network
address of the device.
Communication over
the MedLAN channel
is inoperable.
(MedLAN LEDs may
be off or blinking)
Improper or loose MedLAN
wiring.
Check for secure and correct wiring.
Two or more controls have
the same network address
number.
Check MedLAN address of each
control.
Faulty WTC processor,
faulty DEP-100S or faulty
network power pack.
Replace as necessary.
Symptom
Probable Cause
Corrective Action