WELD INTERRUPTION:
(FAULT) (ALERT)
This fault is generated under three conditions:
•
If the control moves into No Weld Mode while sequencing.
•
If the control powers down while sequencing.
•
If the SLC processor and the WTC weld processor lose
communication while the control is executing a schedule.
I/O UPDATE:
(FAULT)
This fault may occur in one of these conditions:
•
The SLC processor entered Program Mode while the
control was executing a weld sequence.
•
The WTC weld processor and the SLC processor lose
communications for more than the time specified in the
I/O Update Timeout (mSEC): nnn setup parameter. The
fault may be set at any time, including when the control is
initiating a schedule. If this occurs, the schedule is
aborted.
When the control is idled and not initiated, the timeout
interval is fixed at 10 sec.
•
The SLC processor stopped scanning.
•
When the weld processor and PLC processor cannot
communicate over the rack backplane. If this timeout
occurs, major system bus faults are suspect.
•
If the SLC processor moves out of Run Mode while the
control is executing a schedule.
RIO COMM ERROR/NOT IN RUN MODE: (FAULT)
This fault occurs
•
If the host PLC connected to the RIO link moves out of
Run Mode, or
•
The link encounters a fatal communication error while
the control is executing a schedule.
In either case, this fault is flagged regardless of the state of
the I/O VALID input.
WELD PROCEED:
(FAULT) (ALERT)
This fault is generated if the WELD PROCEED input does not
become active within the number of cycles specified in the
function WAIT nnn CY. FOR WELD PROCEED.
Summary of Contents for MedWeld 3005
Page 2: ...YY UTGU T UbQd_bµc 7eYTU V_b D 1 bY ...
Page 84: ...3_ e YSQdY_ c Q T 9 UTGU T UbQd_bµc 7eYTU D 1 bY ...
Page 110: ...GU T CSXUTe Uc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Page 126: ...1TfQ SUT C_VdgQbU 6UQdebUc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Page 144: ...CUde QbQ UdUbc UTGU T UbQd_bµc 7eYTU D 1 bY ...