GU\TCSXUTe\Uc
=UTGU\T# %?`UbQd_bµc7eYTUD)## "
$"!
= #" "%1`bY\" "
parameter is programmed to generate a FAULT, the control
continues with the sequence in No Weld mode to inhibit
weld current from flowing. If programming this parameter as
an ALERT or NONE, it continues with the sequence as
normal.
13
SET VALVE n TOUCH DOWN RESSURE TO mm PSI
(n = 1,2; m = 0–99)
This function sets a reduced "touch down" pressure for the
weld gun to approach and initially touch the work pieces,
prior to clamping them and applying the final pressure
before welding. This prevents the weld gun from closing too
fast and hard on the work pieces.
n
sets the cylinder number: Either #1 or #2. Set the pressure
mm
in the range 0 – 99 PSI.
14
SET VALVE n TIP DRESS RESSURE (PSI)
(n = 1,2; m = 0–99)
This function‘ sets a pressure for the specified weld gun that
can be different from the welding or "touch down" pressure
settings. This is used when running tip dress schedules.
n
sets the cylinder number: Either #1 or #2. Set the pressure
mm
in the range 0 – 99 PSI.
4XLFN5HIHUHQFH
The following list provides a quick reference for functions and
the two-digit code assigned. They are grouped functionally:
'HOD\)XQFWLRQV
01
SQUEEZE nn CYCLES
02
COOL nn CYCLES
03
HOLD nn CYCLES
04
OFF nn CYCLES
05
INITIAL SQUEEZE nn CYCLES
07
WAIT nn CYCLES
$9&)LULQJ0RGH
20
WELD nn CY/IMP mm %I*
21
TEMPER nn CY/IMP mm %I
22
PREHEAT nn CY/IMP mm %I
23
POSTHEAT nn CY/IMP mm %I
Summary of Contents for MedWeld 3005
Page 2: ...YY UTGU T UbQd_bµc 7eYTU V_b D 1 bY ...
Page 84: ...3_ e YSQdY_ c Q T 9 UTGU T UbQd_bµc 7eYTU D 1 bY ...
Page 110: ...GU T CSXUTe Uc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Page 126: ...1TfQ SUT C_VdgQbU 6UQdebUc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Page 144: ...CUde QbQ UdUbc UTGU T UbQd_bµc 7eYTU D 1 bY ...