If the computer interface pod is faulted (the Red LED is ON), power the
interface pod switch OFF, then ON, to clear the fault.
4.
Select
YES
to go on-line. Note the
ONLINE
status at the
bottom of the main screen.
1RGH&RPPLVVLRQLQJ³5RERW
Follow these steps:
1.
Under
UTILITIES
,
select
NODE COMMISSIONING
.
2.
Select
MINI WHO
to confirm the node addresses. (They will
likely be zero for the DeviceNet card. The computer interface
is 62.)
1^5hQ]`\U*
In this example,
MINI WHO
found node addresses 00 and 62.
Configure the DeviceNet Card as
NODE 30
with the following
procedure. This is used in any control from single- through six-
pack:
1.
Close
MINI WHO
.
2.
Change the current node address to the value found using
MINI WHO
.
3.
Change the new node address to NODE 30 and a 500 kB/sec.
data rate. Do it in two steps, as follows:
Node 62 @ 125 kB
Select GO ON LINE
then YES, GO ON LINE
Node 62 @ 500 kB
Select GO ON LINE
then YES, GO ON LINE
Node 62 @ 250 kB
Select GO ON LINE
then YES, GO ON LINE
WTC NODE ADDRESSING METHOD
ROBOT [5 byte transfer]
NODE 03 Used as the Master to control
(REV 02.04 & UP)
a WTC Weld Control
NODE 30 In a WTC Weld Control, for
(REV 02.04 & UP)
SCR1 through SCR3
Summary of Contents for MedWeld 3005
Page 2: ...YY UTGU T UbQd_bµc 7eYTU V_b D 1 bY ...
Page 84: ...3_ e YSQdY_ c Q T 9 UTGU T UbQd_bµc 7eYTU D 1 bY ...
Page 110: ...GU T CSXUTe Uc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Page 126: ...1TfQ SUT C_VdgQbU 6UQdebUc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Page 144: ...CUde QbQ UdUbc UTGU T UbQd_bµc 7eYTU D 1 bY ...