dnet_map Welder Outputs—Node 30
Note:
The above information will be located in the SLC image table of the Scanner slot beginning with word #1. (i.e., If the scanner is
located in slot #2, word 0 will contain the status/control information, word #1 will contain bytes 0 & 1, word #2 will contain
bytes 2 & 3, etc.)
Host Input Image Table (Node 30)
Bit
Global
SCR#7
SCR#8
SCR#9
SCR#10
SCR#11
SCR#12
Byte 0
Byte 1
b
Byte 2
b
Byte 3
b
Byte 4
b
Byte 5
b
Byte 6
b
Byte 7
b
00
ID Bit #0
Reserved
I/O ACTIVE
I/O ACTIVE
I/O ACTIVE
I/O ACTIVE
I/O ACTIVE
I/O ACTIVE
01
ID Bit #1
Reserved
WELD IN
PROGRESS
WELD IN
PROGRESS
WELD IN
PROGRESS
WELD IN
PROGRESS
WELD IN
PROGRESS
WELD IN
PROGRESS
02
ID Bit #2
Reserved
NO FAULT
NO FAULT
NO FAULT
NO FAULT
NO FAULT
NO FAULT
03
SIZE BIT #0
Reserved
ALERT
ALERT
ALERT
ALERT
ALERT
ALERT
04
SIZE BIT #1
Reserved
END OF
STEPPER/END
OF CAP LIFE
END OF
STEPPER/END
OF CAP LIFE
END OF
STEPPER/END
OF CAP LIFE
END OF
STEPPER/END
OF CAP LIFE
END OF
STEPPER/END
OF CAP LIFE
END OF
STEPPER/END
OF CAP LIFE
05
SIZE BIT #2
Reserved
STEPPER IS
RESET
STEPPER IS
RESET
STEPPER IS
RESET
STEPPER IS
RESET
STEPPER IS
RESET
STEPPER IS
RESET
06
SIZE BIT #3
Reserved
WELD
COMPLETE
WELD
COMPLETE
WELD
COMPLETE
WELD
COMPLETE
WELD
COMPLETE
WELD
COMPLETE
07
SPARE
Reserved
READY TO
WELD
READY TO
WELD
READY TO
WELD
READY TO
WELD
READY TO
WELD
READY TO
WELD
Summary of Contents for MedWeld 3005
Page 2: ...YY UTGU T UbQd_bµc 7eYTU V_b D 1 bY ...
Page 84: ...3_ e YSQdY_ c Q T 9 UTGU T UbQd_bµc 7eYTU D 1 bY ...
Page 110: ...GU T CSXUTe Uc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Page 126: ...1TfQ SUT C_VdgQbU 6UQdebUc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Page 144: ...CUde QbQ UdUbc UTGU T UbQd_bµc 7eYTU D 1 bY ...