3.12 Drive Bearing
Refill the fluid in the drive-side cylinder bearing housing every 500 hours of operation. Remove the
top and bottom oil plugs. Pour an Automatic Transmission Fluid (ATF) such as Dexron III ATF into
the top hole until it begins to flow from the bottom hole. Reinstall the square oil plug to the bottom
hole and the vented oil plug to the top hole.
See Figure 3-7.
FIG. 3-7
500
Vented plug
Top hole
Bottom hole
Square plug