26
Force 30 Owners Manual
2015
Sweeping the Heat Exchanger Tubes
Regular cleaning of the heat exchanger tubes is done
from the top by removing the flue tube clean out door
on the top of the furnace. Ensure the furnace has had
ample time to cool before cleaning the heat exchanger
tubes and emptying the ash box. Dispose of ash in a
metal container away from combustible materials.
When cleaning the heat exchanger tubes ensure that
you do not damage the ceramic insulation in the pro
-
cess.
NOTE: Make sure the cables and hoses are not dam
-
aged during the cleaning process.
Unscrew the two black knobs and remove the tube ac
-
cess cover from the top of the furnace.
Remove the diverting plate.
Clean each tube with the wire brush. vacuum any ash
out of the top tube access box.
The Force 30 and Renovator should be cleaned regularly. It is recommended that the furnace and burner
should be cleaned every 2 weeks or 1000 pounds of fuel used. CAUTION: THE BURNER AND FURNACE MAY
BE HOT!
Maintenance