Force 30 Owners Manual
2015
Programming and information about the PLC
To make changes to the settings of the PLC, use button 1 to scroll between menus. Once you have found the
menu with the setting you wish to change, press the white button on the right with button 4.
Once the white button and button 4 have been pressed one of the values that can be changed is now blinking.
To change the desired value, adjust with buttons 2 (down) and 3 (up).
Buttons 1 and 4 let you scroll between the different settings on each menu.
Press the menu/ok to save any changes made. The value should stop blinking.
The burner is not adjusted from the factory. The burner has to be adjusted with a flue gas instrument the first
time the burner is fired and after a change in fuel brand/quality.
NOTE: The Force 30 is shipped with a protec
-
tive coating on the heat exchanger to prevent corrosion. This will burn off during the first time firing of the
furnace and may briefly produce a blue smoke.
1. Fill the feed auger with pellets before you connect the tube to the burner. Connect cable of the auger
with the power cable for the burner and run it manually until pellets have been fed out from the auger
for about 15 minutes. Insert the auger tube into the tipping chute when complete.
2. Setting of start dose (the amount of pellets at ignition). A good start dose is approx. 150 grams
(5.25 ounces) We recommend manually measuring the start dos. The start dose is approx. equal to the
volume of an 8.5 oz cup.
3. To adjust amount of fuel for operation, a flue gas instrument must be used
. The proper adjustment is
needed to obtain the cleanest and most efficient burn. This should be made by your authorized
WoodMaster Dealer.
1.
This is the default home screen. No changes can be made
in this menu. Pressing the White button and the Menu/Ok
button will briefly change the display to show the date/time
screen. This will change back on its own.
2.
In this menu you can set the start dose. Here you choose
how many seconds the auger takes to feed the optimal start
dose (approx. 150 grams or 5.25 oz) of fuel pellets. Factory
default is 70 seconds. This menu also handles the desired
value of the photo sensor that controls the flame at combus
-
tion. When the sensor feels the flame has reached input
value the burner switches to the soft start in the combustion.
The photo sensor value can also be read in real time.
1
2
3
4
Menu/Ok
RENOVATOR
v20
STARTDOS
PHOTO000
SCREW ON +070.0
PRESET PHOTO+10
Menu/Ok
1
2
3
4