17
Force 30 Owners Manual
2015
Installation
On Board Air Cleaner Installation
The Renovator Pellet Burner has the capability to clean the fire pot with compressed air supplied by an on
board air compressor. This allows for easier ignition as well as lower maintenance. Below is a brief explanation
of the installation process.
NOTE: Disconnect all power during installation.
Disconnect the wiring and remove the cover of the
burner.
Note: The burner does not need to be removed
from the boiler to perform this installation, the burner
is shown off the boiler for reference only.
The location
of the air line connector is below the combustion fan
on the left side. Connect the supplied air hose to the
air line connector on the burner.
Unpack the air compressor. Connect the air hose to the
air compressor via the quick connect. Make sure the air
compressors power switch is left in the “on” position.
NOTE: Do not modify the length of the air hose.
Plug the supplied air compressor power cord adaptor
into the burner. Plug the air compressor power cord
into the adaptor. Replace the burner cover. Place the
air compressor next to the furnace, making sure the
air line and power cord are clear of the ash door and
other heat sources.
If you do not wish to use the on board air cleaner, you still need to supply compressed air to the burner for
cleaning. Northwest Manufacturing, Inc. offers an adapter (Part Number: 0020-213) that will allow you to con
-
nect the air hose to a full size air compressor. Whenever the boiler is operational there needs to be a constant
supply of compressed air of 80-90 psi available to the burner.