31. Adjusting the maximum heating
output
0,0
5,0
10,0
15,0
20,0
25,0
30,0
0
20
40
60
80
100
120
Output setting (parameter HG04)
The output setting can be modified with Wolf control accessories with eBUS capability.
The heating output is determined by the gas fan speed. By reducing the gas fan speed in accordance with the table, the maximum
heating output at 80/60 °C is adjusted.
Limiting the maximum heating output relative to a flow/return temperature of 80/60 °C
Display value [%]
Heating
output
[kW]
Table: Output settings
24 kW appliance
Display value (%)
1)
30
40
50
60
70
80
90
100
Heating output (kW)
4.8
7.3
10.2 13.0 15.8 18.6 21.5 24.3 27.1
20 kW appliance
Display value (%)
1)
30
40
50
60
70
80
90
100
Heating output (kW)
3.8
5.5
7.9
10.3 12.6 15.0 17.4 19.8 22.2
14 kW appliance
Display value (%)
1)
30
40
50
60
70
80
90
100
Heating output (kW)
1.9
3.5
5.1
6.7
8.2
9.8
11.3 12.3 13.5
24 kW appli
-
ance
20 kW appli
-
ance
14 kW appli
-
ance
1)
minimum appliance output