W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual
18
6.2
Enter AT command Mode
W7500S2E-R1 has two modes, AT command mode and data mode. In AT command mode, user
could use serial terminal or through user’s MCU main board to configure the parameters of the
module. Command enter will return a value (In echo mode, it will show the serial message). In
data mode, all the commands except the “+++” would be ignored to the module. Thus, entering
the “+++” command will change the module into AT command mode.
Note: ”+++” command rules: It needs to send “+” symbol continuously in 3 times to through
serial interface to the module. This command requires 1 second gap each before and after this
command has entered to activate the correct response from W7500S2E-R1. If not, it will
consider as user’s data input. This command does not require CRLF (Carriage-Return
Line-Feed)(\r\n). The factory default setting of the module is in AT command mode.
6.3
AT command list
The following list is the AT command (case insensitive)list and related return value that supports
by WIZS2E module. The type “R” stands for read only. “R/W” means it could read and write. “<
>” it means mandatory parameter. “[ ]” it means optional parameters. AT commands are
classified into four categories: Basic commands, Control commands, device configuration
commands and serial configuration commands
6.3.1
System control command list
Features
Command
Terminal check
AT
Entering command mode
+++
Exit command mode
AT+EXIT
6.3.2
Control command list
Features
Command
Typ
e
Max length
Parameters / Description
Echo
AT+ECHO
R/W
1
0: Close echo
1: Open echo (Default)
List of commands
AT+LIST
R
0
Queries only: AT+LIST?
List of default / current values
AT+PRE
R
0
Queries only: AT+PRE?
Factory reset
AT+DEFAULT
W
15
Required Password (Case sensitive)
Reset
AT+RESET
W
15
Required Password (Case sensitive)
Ethernet send counter
AT+NETSEND
R
0
Queries only: AT+NETSEND?
Ethernet receive counter
AT+NETRCV
R
0
Queries only: AT+NETRCV?
Device uptime
AT+RUNTIME
R
0
Queries only: AT+RUNTIME?
Firmware version
AT+VER
R
0
Queries only: AT+VER?