![Wiznet W7500S2E-R1 User Manual Download Page 27](http://html1.mh-extra.com/html/wiznet/w7500s2e-r1/w7500s2e-r1_user-manual_990610027.webp)
W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual
23
6.4.2.9
Ethernet receive counter (AT+NETRCV)
Command format
Description
Usage
AT+NETRCV?\r\n
Nil
Query the byte of data received from Ethernet interface
return value
[NETRCV] Value is: <number>\r\nOK\r\n
Value ranged is 0 to 4,294,967,295.
6.4.2.10
Device uptime (AT+RUNTIME)
Command format
Description
Usage
AT+RUNTIME?\r\n
No
Query current value
Return value
[RUNTIME] Value is: <time>000-00-18-26\r\nOK\r\n
Received the device uptime of the WIZS2E module; Unit: seconds
Return format: ddd-hh-mm-ss
6.4.2.11
Firmware version (AT+VER)
Command format
Description
Usage
AT+VER?\r\n
Nil
Query current value
Return value
[VER] Value is: <firmware version>\r\nOK\r\n
6.4.3
Device configuration command list
6.4.3.1
Device ID (AT+SN)
Command format
Description
Usage
AT+SN?\r\n
Nil
Query current value
Return value
[SN] Value is: <device ID>\r\nOK\r\n
Device ID of the WIZS2E module for identification. It contains the last 6 HEX of the MAC address. This
attribute is read only.
6.4.3.2
Device type (AT+TYPE)
Command format
Description
Usage
AT+TYPE?\r\n
Nil
Query current value
Return value
[TYPE] Value is: W7500S2E-R1\r\nOK\r\n
Device type is clarifying the device is a serial to Ethernet module. This attribute is read only.
6.4.3.3
Device name (AT+NAME)
Command format
Description
Usage
AT+NAME=<name>\r\n
<name>
Device name: it can be any character; the maximum
length is 16 bit; user defined for identification
Define new value
AT+NAME?\r\n
Query current value
Return value
[NAME] Value is: <name>\r\nOK\r\n
Device name can be user defined for identification.
Remarks: When using NetBIOS name function, device name should follow the “AT+NETBIOS” naming rules
.