![Wiznet W7500S2E-R1 User Manual Download Page 40](http://html1.mh-extra.com/html/wiznet/w7500s2e-r1/w7500s2e-r1_user-manual_990610040.webp)
W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual
36
Figure 7-3 Basic information page
Product Information
•
Device Type: factory default is W7500S2E-R1, cannot be modified.
•
Device Name: name of module, the factory default is W7500S2E-R1 and it could be
changed from the advanced setting page
•
Firmware Version: shows the firmware version
•
Serial number: the last 3 parts of the serial number will be equal to the last 6 characters
of the MAC address of the module
•
Temperature: Shows 0
o
c degree, reserved function
•
Run Time: W7500S2E-R1’s operation time. Unit: seconds
•
Serial Rx: Shows the bytes of data received at the serial interface
•
Serial Tx: Shows the bytes of data sent from the serial interface
Network Information
•
DHCP: on/off; Shows the DHCP mode is it active, default: off *
•
IP Address: Shows the current IP address, default: 192.168.1.88 *
•
Subnet: Shows the current subnet mask, default: 255.255.255.0 *
•
Gateway: Shows the current gateway, default: 192.168.1.1 *
•
DNS Server: Shows the current DNS address, default: 114.114.114.114 *
Socket Information
•
Mode: Shows the operating mode, default: TCP Server *
•
Local Port: Shows the local port, default: 5000 *
•
Remote Host: Shows the Remote Host IP address, default: 192.168.1.99 *
•
Remote Port: Shows the Remote Host Port number, default: 5000 *
UART Information
•
Baud Rate: Shows the baud rate, default: 115200 *
•
Date Bit: Shows the data bit, default: 8 *
•
Parity: Shows the parity bit, default: NONE *
•
Stop Bit: Shows the stop bit, default: 1 *