W7500S2E-R1 serial to Ethernet module
W7500S2E-R1 user manual
37
•
Flow Control: Shows the flow control settings, default: NONE *
* These settings could be updated in the “Basic Settings”
7.2
Basic Settings
Figure 7-4 shows W7500S2E-R1 basic settings page. It is separate into four sections; The
following paragraph talking about each section.
Figure 7-4 Basic setting page
Network Setting
•
MAC Address: Shows MAC address provided with the module, user cannot modify
•
Use DHCP: DHCP mode option, default: uncheck
#
•
IP address: Shows the IP address, default: 192.168.1.88
#
•
Subnet Mask: Shows the Subnet Mask, default: 255.255.255.0
#
•
Gateway: Shows the Gateway, default: 192.168.1.1
#
•
DNS Server: Shows the DNS address, default: 114.114.114.114
#
Socket Setting
•
Start Mode: Startup mode of the module, it could be “AT Command Mode” or “Data
Mode”
#
•
Socket Type: The module’s operating mode: There are 3 types to use. TCP server, TCP
client and UDP mode
•
Remote Host: Shows remote host IP address, default: 192.168.1.99; It accepts IP address
or domain name inputs
#
•
Remote Port: Shows remote host port number, default: 5000
#
•
Local Port: Local port number, default: 5000. The value range is 0 to 65535 (Port 80 has
used for web port. Please avoid using this port number.)
#
•
Bind Local Port: Binding Local Port option, default: uncheck, only available on TCP
client mode
#
UART Setting
Baud Rate: The baud rate option, default: 115200, between 1.2Kbps to 1.152Mpbs
#
Data Bit: The data bit option, default: 8, it could set into 7 or 8 bits
#