SmartPAC PRO Installation Manual
1143200
Chapter 2 – Installing SmartPAC PRO
39
Figure 2-12. Installing Suppressors Across an AC Load
Figure 2-13. Installing a Diode Across a DC Load
Wiring Setup Mode Circuit
SmartPAC PRO Setup mode allows you to disable green sensors and parts/batch counters, using a
remote switch. Typically, the Setup mode circuit is enabled when Inch mode is selected on your
clutch/brake control. When you inch the press, SmartPAC PRO will not stop the press when a fault
condition is detected. The Setup mode terminal can be wired to an extra contact on the Inch position
of the Stroke Select keyswitch of your press control, or you can use an external switch to activate the
circuit. If you intend to use the Setup mode circuit, plan how you will run your wiring for this
connector now so you do not have to disconnect conduit or rerun wires through conduit later.