Byte No.: 2 Switches
Bit
Function
0="0"
Carrier in home position
1="0"
Cutter in home position
2="0"
Cover open
3="1"
DIP1 on
4="1"
DIP2 on
5="1"
DIP3 on
6="1"
DIP4 on
7="1"
not used
Byte No.: 3 to 7
not used, fixed 0
ESC + 5
A power failure can be detected. A data field of 1 byte (n2 = 1) is trans-
mitted, where bit 0 = 1 means “power failure”. The bits 1 to 7 equal 0
and are not used. The bit “power failure” is transmitted after switching on
the ND 69. After transmission of the command ESC + 5 it will be deleted.
ESC + 128
When the status byte reports a power-up error, a more detailed
description of the cause of the error is provided by this enquiry. A data
field of 2 bytes (n2 = 2) with the following meaning is transmitted:
Byte 1
Contents
Error Messages
= 66H
No Error
= 01H
CPU Error (commands)
= 02H
CPU Error (internal RAM)
= 20H
External RAM Error
= 30H
EPROM Error
Byte No.: 2 not used, fixed 0
Control Sequences
Description
GB - 75