Self Test
Self Test
The printer executes a self test if either the receipt or journal line feed button is pressed
while the device is being switched on. Depending on the pressed button the following
printout is produced either at the journal station or the receipt station.
A 24V measurement is carried out, and the result is printed
(max. deviation:
±
10%).
Default paper width setting
The device configuration is printed.
The status of all the sensors and the cover switch are checked
and printed.
Firmware version, in this example: Promversion 03,
Plug-in place 01 and sub-version 44
The power-up diagnosis is started. The result of the hardware
check is clearly printed at the receipt and/or journal station.
DIP switches (see also page 8 onwards)
Default:
1
ON
2
OFF
3
OFF
4
OFF
PCB-Version (Printed Circuit Board Version), i.e. 1 stands for
PCB-Version 1, >=2 stands for PCB-Version 2 or higher
Circulation number
Installation
Self Test
GB - 15