Firmware Release Notes
SM3BAT User Guide
page
74
BIOACOUSTIC MONITORING SYSTEMS
■
Revised the
AUTO
sample rate calculations. See Program Commands
section of User Guide for new
AUTO
settings.
■
Fixed problem with ZC file timestamps, introduced in 1.1.9, causing
duplicate file names in zero-crossing only mode.
■
Fixed enforcement of maximum trigger length on two-channel recordings.
1.1.9
■
Fix possible GPS synchronization bug in which a recording may be marked
as synchronized when it is not.
■
Correct microphone calibration mode to read dBVrms. This version will
read 1.6dB lower for the 40kHz measurement than prior releases.
■
Implement microphone sensitivity meta data to account for gain.
■
Re-ordered built-in programs such that sunset-to-sunrise comes before
sunrise-to-sunset.
1.1.8
■
Significant improvements and fixes to native crossing recording.
1.1.7
■
Fixed problem causing some flash cards to fail to initialize after power up.
■
Fixed potential problems that could lead to flash card filesystem corruption
under some circumstances.
■
Improved flash card performance to decrease delays in back-to-back
recordings as the number of recordings grows.
1.1.5
■
Fixed a bug that could cause reliability issues.
1.1.4
■
Added a new programming command "FEATURE". This is for advanced
use and is not a required command by the program checker. The first
parameter is a number from 1 to 16 and the second parameter is OFF or
ON. By default, all features are OFF. The only feature implemented initially
is FEATURE#01 which, if ON, disables the LED blinking during
recording. Thus, you can insert into the top of a program "01 FEATURE 01
ON" to disable the LEDs. This capability may be used to add additional
features in the future.
■
Improved performance of back-to-back triggers.
■
Added a means to disable file scrubbing (deleting files with no bat
echolocations detected) in triggered WAV mode so that no files will be
deleted. If DMIN and DMAX are set to OFF then scrubbing is disabled.
■
Changed built-in program DMIN values to 1.5ms from 2.0ms for better
detection of Myotis and other species in cluttered environments.
■
Fixed a bug when "backing up" to start the schedule immediately
with NAP mode or zero crossing enabled, which caused constant "auto-
leveling" activity.
Summary of Contents for sm3bat
Page 6: ......
Page 71: ...SM3BAT User Guide SM3BAT Specifications page 65 BIOACOUSTIC MONITORING SYSTEMS ...
Page 75: ...SM3BAT User Guide SM3BAT Specifications page 69 BIOACOUSTIC MONITORING SYSTEMS ...
Page 76: ...SM3BAT Specifications SM3BAT User Guide page 70 BIOACOUSTIC MONITORING SYSTEMS ...
Page 77: ...SM3BAT User Guide SM3BAT Specifications page 71 BIOACOUSTIC MONITORING SYSTEMS ...