Developing Custom Programs
SM3BAT User Guide
page
44
BIOACOUSTIC MONITORING SYSTEMS
This command is only relevant if
TRGLVL
is not
OFF
.
See
DMIN
for more information on how the scrubber uses this value.
See
TRGLVL
for more information on how the trigger uses this value.
DMIN <dur-channel-0> <dur-channel-1>
Specifies the minimum duration for a signal in the specified frequency range
to be a valid signal to satisfy the scrubber Values are 0.1 – 800.0 msec in 0.1-
msec steps, or
OFF
.
The scrubber automatically deletes files where no suitable bat echolocation
is detected. The scrubber looks for at least two narrow band signals of at
least this
DMIN
duration and shorter than
DMAX
and within the frequency
range specified by
FRQMIN
and
FRQMAX
. If
two such signals exist, the file
is saved, if they are not, the file is not saved. 1.5ms is recommended for
recording bats.
If
TRGLVL
is not
OFF
, the files are scrubbed based on this field and
DMAX
.
If you do not want to scrub files, set this command and
DMAX
to
OFF.
DMAX <dur-channel-0> <dur-channel-1>
Specifies the maximum duration for a signal in the specified frequency
range to be a valid signal to satisfy the scrubber. Values are 0.1 msec – 800.0
msec in 0.1-msec steps, or
OFF
.
OFF
is recommended for recording bats.
The shortest
DMAX
chosen between channel 0 and 1 will also truncate the
total length of a WAV while recording on stereo channels. This means that if
one channel is in mid trigger and has not yet reached its
DMAX
and the
other channel does reach
DMAX
, the first channel will be truncated shorter
than its programmed
DMAX
.
See
DMIN
for more information on how the scrubber uses this value.
TRGLVL <level-channel-0> <level-channel-1>
Specifies the digital trigger level. Thresholds are either absolute (negative
values) or relative to the measured noise floor (positive values). The range is
-88 dB
–
+88 dB in 1-dB steps or
OFF
or
AUTO
selection is available.
If either channel value is not
OFF
, then the
FRQMIN, FRQMAX, DMIN,
DMAX, TRGWIN, and TRGMAX
commands are required before the next
RECORD
command.
The trigger is satisfied if a signal exceeds the specified level within the
frequency range defined by
FRQMIN
and
FRQMAX
.
Turning on triggers will also activate file scrubbing. For information on
scrubber function and how to turn off the feature, see
DMIN
.
Summary of Contents for sm3bat
Page 6: ......
Page 71: ...SM3BAT User Guide SM3BAT Specifications page 65 BIOACOUSTIC MONITORING SYSTEMS ...
Page 75: ...SM3BAT User Guide SM3BAT Specifications page 69 BIOACOUSTIC MONITORING SYSTEMS ...
Page 76: ...SM3BAT Specifications SM3BAT User Guide page 70 BIOACOUSTIC MONITORING SYSTEMS ...
Page 77: ...SM3BAT User Guide SM3BAT Specifications page 71 BIOACOUSTIC MONITORING SYSTEMS ...