4. Part Replacement
4.7 DIMM Replacement
Figure 80:
Removing System Fans
Step 12 :
Uninstall the rest of the system fans in the same manner as the first.
Step 13 :
Uninstall server cover panel on the side of the enclosure that contains the failed DIMM.
Note:
Uninstall the server cover panel on the side that requires the DIMM
replacement. The same steps to uninstall the server cover panel apply to both
sides of the enclosure with the exception of the number of screws that secure
the server cover panel. From the rear of the enclosure, the left panel contains
two screws. The panel on the right side of the enclosure contains one screw.
a.
Remove the screws that secure the server cover panels to the chassis using a T7 Torx
screwdriver.
Note:
When at the rear of the enclosure, the left server cover panel
contains two T7 Torx screws. The left server cover panel contains only
one T7 Torx screw.