Installation and operating instruction
Combustion manager W-FM 100 und W-FM 200
6 Operation
83054802 1/2018-07 La
87-228
Post-purge position
Parameter
PostpurgePos
defines the positions for post-purge in phases 74
to 78. The exception is auxiliary actuator 3 (flue gas recirculation), which only drives
to the post-purge position after phase 76.
The speed
PostpurgePosVSD
must not be set below 10 %.
Program stop
Using parameter
ProgramStop
, the program sequence can be stopped in
defined phases. Parameter
ProgramStop
can also be called up in menu
Param
& Display/RatioControl
.
Setting
Function
deactivated
No program stop
24 PrePurgP
Stop in phase 24, pre-purge position
32 PrePFGR
Stop in phase 32, auxiliary actuator3 in pre-purge position
36 IgnitPos
Stop in phase 36, ignition position
44 Interv 1
Stop in phase 44, flame signal
52 Interv 2
Stop in phase 52, ignition pilot valve OFF
72 PostPPos
Stop in phase 72, post-purge position
76 PostPFGR
Stop in phase 76, auxiliary actuator3 in post-purge posi-
tion
Summary of Contents for W-FM 100