Operation
Parameter
Definition
Setting Range
suppress the spike effectively. It is suggested to measure the actual height of the spike with a laser
interferometer or other measuring device in debugging, and then set this parameter as 0.3 to 3
times of spike height. Compensation result is also related with compensation time and intensity.
Compensation delay time:
the spikes may not appear exactly at the four quadrant positions due to
mechanical properties of machine tool, but a little distance away from the quadrant points. Estimate
the time to travel this distance and then set the time as the value of this parameter.
Compensation intensity:
the larger the value is, the more obvious the compensation result will be.
3.12 Log
Under [Diagnosis] function section, press F7 to enter [Sys info] sub-function screen and then press F5 to
enter log interface, as shown in Fig. 3-46.
Fig. 3-46 Log Screen
[Log] screen records important operations and system events, and users can not only browse the log
information since this time start-up but also view the history records. Besides, pressing L can export log
to external equipment such as USB while pressing S deletes it. The introduction to the manipulation
buttons at the bottom is as follows:
Show All / Show Today
Their shortcut keys are F1 and F2 respectively.
The two buttons correspond to two kinds of information, that is all the log information and today
‟s log
information.
Show Info / Show Warning / Show Error / Show System
Their shortcut keys are F3, F4, F5 and F6 respectively.
System information can be divided into three types, including general information, alarm information and
error information.