Specialized Concentrated Focused
「
54
」
Operation
negative error is executed. It applies to when backlash is unstable.
3.11.1.3
Software Interface and Operation
Press SPF4 to enter function section [Parameter]. Under [Parameter] function section, press F6 to enter
[Screw error compensate] interface shown as Fig. 3-39. See corresponding manipulation buttons
function as follows.
Fig. 3-39 Compensation Parameters Setting
Insert
Used for inserting compensation data. This button pressed, users can insert a new group of data in the
blank row. Note that continuous inserting of multi-blank-line is prohibited and next inserting is allowed
after previous one is completed.
Delete
Used for deleting the currently selected data.
Setup
Press this button to open setup dialog box, as shown below. Please input start position, interval and
amount to set compensation position as a whole. Used together with the laser measurement of program
wizard, the compensation value calculated by the laser measurement can be set in this interface. See
3.13.1 for laser measurement introduction.