Cooling System
8.1
Cooling System Disassembly and Assembly
8.1.1 Cooling System Exploded View
The cooling system ensures that the engine can operate at the proper operating temperature.
Forced circulation cooling is most effective at keeping the engine within the normal operating
temperature range. The cooling system primarily consists of the water pump, fan, expansion
water tank, water tank and thermostat.
Fig. 8-1 Exploded view of cooling system
No.
name
No.
name
No.
name
1
radiator
4
Water pump
7
Intermediate plate
2
fan
5
Thermostat
3
Fan bracket
6
Water input pipe
8.1.2 Cooling System Disassembly Procedure
1.
Remove the water tank.
2.
Remove the fan.
3.
Remove the belt.
4.
Remove the generator and other auxiliary parts.
1
2
3
5
4
6