Redundancy Controller
Page
17
Document Number: 90-005-0030_E
Preparation
Required Tools / Supplies
Torque driver
Cable manufacturing tools
Installation Precautions / Prerequisites
C A U T I O N
Moisture sensitive.
The unit is not weatherized. Install in a weatherized location
using good commercial practice and UV-rated materials.
Inspection and Unpacking
Keep the shipping box and all packing materials for future use, including return of the
unit for repair.
Inspect the unit for any visible damage. If the unit is damaged, follow the warranty RMA
instructions.
Remove any foreign objects such as packing material.
Verify that the connector pins are intact and ready for connection.
Installation
C A U T I O N
Airflow.
The slots and openings provide forced air convection ventilation
and air flow.
Do not block these openings.
When mounting the unit in a closed area, such as a building or radome, ensure that proper
ventilation is provided. The internal operating temperature should not exceed the maximum rated
temperature.
Install the unit according to standard practice. The RMC can be mounted in a standard
19” rack mount cabinet.
Position the RMC in the appropriate rack position (it fits into a 1U space).
Secure the RMC to the rack with two 10-32 screws installed on each side of the RMC
front panel. Torque to 25-28 inch pounds.
W A R N I N G
High Power RF Hazard.
Do not energize the SSPAs / BUCs until all RF output
waveguides are properly connected to the rest of the system or
to a high power load..
Do not open the RMC. Never put any object through the slots or
openings as this could result in touching dangerous voltage
points, short-circuiting parts, electric shock, fire or electrostatic
discharge.