Redundancy Controller
Page
7
Document Number: 90-005-0030_E
Specifications
Performance
Switch operation
Manual or automatic, user selectable
Muting
Wavestream SSPAs/BUCs: automatic muting of transmission when
baseball switch switches between units.
Switching time
Less than 1 second
Supported units
Wavestream:
8-40 W Ku-Band SSPA / BUC
100 W Ku-Band SSPA / BUC
200 W Ku-Band SSPA / BUC
600 W C-Band SSPA / BUC
Non-Wavestream:
Any SSPA or TWTA with discrete system status line
Monitor & Control
Monitor & Control
Ethernet
Status LEDs
Indicates Tx active, summary fault, serial link, 10 MHz lock
Display interface
Quick status review, setup, manual control
Power
Prime power, AC
90 - 264 VAC, 50-60 Hz
Environmental
Ambient temperature
Operating: -0°C to +50° C (-32° F to +122° F)
Non-operating: -40° C to +70° C (-40° F to +158° F)
Relative humidity
0
– 95% noncondensing
Altitude
10,000 feet above mean sea level
Physical
Size
19” W [rack mount] x 1.72” H [1U standard] x 9.64”D [from front panel]
Weight
4.2 lbs (1.568 kg)