Redundancy Controller
Page
19
Document Number: 90-005-0030_E
Non-Wavestream SSPAs
This procedure assumes that there are two operating SSPAs and that the waveguide switches are
already installed.
1.
Perform a continuity check on all cables prior to installation.
Ensure that cable for J2 is correctly wired. Refer to
Verify that pins 1 and 2 and 5 and 6 are correctly wired.
Install the cables J2 through J8 into the back of the RMC as applicable.
Wavestream SSPAs / BUCs
This procedure assumes that there are two operating Wavestream SSPAs / BUCs and that the
waveguide switches are already installed.
Perform a continuity check on all cables prior to installation.
Install the cables J2 through J8 into the back of the RMC as applicable.
Connect Cables
1.
Route the cables out of the cabinet. Be careful not to strain the connectors on the back of the
RMC. Use cable ties and strain reliefs to secure the cables.
2.
Connect the cables to the SSPAs and waveguide switches.
3.
Connect the J2 alarm and general output cable.
4.
Connect the Ethernet cable to the computer system if applicable.
W A R N I N G
Wiring.
Incorrect cable wiring can permanently damage this unit.
N o t e
If a cable will be 6 feet or longer, Wavestream recommends use
of multi-conductor shielded cable to reduce noise pickup.
Connect the shield to the case.