Redundancy Controller
Page
28
Document Number: 90-005-0030_E
The following SSPA status definitions are displayed on the GUI and indicate the status of the
SSPAs. The following definitions can also be found in the appropriate manual associated with each
power amplifier. For complete definitions, refer to the SSPA manual.
To view the redundant SSPA information, click the
Rackmount Thread
pull down menu.
Select
View Thread Status,
Thread B
.
Unit Information
Information about the SSPA that the GUI is communicating with and is indicated
at the left upper portion of the screen.
Serial Number
Provides the unit serial number.
Model Number
Provides the model number of the unit.
Firmware Version
Provides the version of firmware that is running on the unit.
Temperature
Temperature
Displays the temperature of the unit in degrees C.
Fan Speed
Displays the fan speed. Fan speed depends on the system temperature and
automatically increases or decreases to control the overall temperature.
Power Supply
Drain Voltage
Displays the analog output voltage from the internal power supply.
Drain Current
Displays the analog output current from the internal power supply.
Unit Led
LED
Indicates if the LEDs on the unit have been enabled or disabled via Save Led
Settings (Save Settings → Save Led Settings).
Unit Status
Summary Fault
[OK/Fault]. Displays the status of the Summary Fault signal. If the
signal reads Fault, one of the following has occurred:
the unit is over temperature
the unit cannot safely turn on due to bias problems
HPA
[On/Off]. Displays the status of the u
nit’s amplifier
RF
RF Input Power
Where applicable, displays the input power level in dBm.
RF Forward Power
Where applicable, displays the analog RF forward power level (output) in dBm.
Note that for RF forward power readings below 25 dBm, the forward power may
not read accurately.
RF Reflected Power
Where applicable, reads the analog RF reflected power level (reflected back into
unit). The approximate output power in dBm is displayed. For RF reflected power
readings below 25 dBm, the forward power may not read accurately.
Step Attenuation
Where applicable, displays the gain attenuation.
10MHz Reference
[OK/Fault]. Where applicable, displays the status of the BUC 10 MHz reference
signal If the display shows Fault, the unit has lost lock on the 10 MHz reference
signal.