Redundancy Controller
Page
21
Document Number: 90-005-0030_E
Menu Definitions
MONITOR
Identifies the SSPA [A or B] being monitored and brief status information. If the
SSPA is muted INHIBITED will be displayed.
Summary
[
OK/Fault
] Summary fault status.
Tx
[
Active/Inactive
] Status of transmit.
RF Fwd Power
Provides the RF forward power in dBm.
MENU/CONTROL
Lists submenus that may be accessed. Press Enter to access it.
SSPA-A
Selects SSPA-A submenu.
SSPA-B
Selects SSPA-B submenu
TX SW
Select which position the TX switch will be active:
A=1 and 2, 3 and 4
B=1 and 4, 2 and 3
RX SW
Select which position the RX switch will be active:
A=1 and 2, 3 and 4
B=1 and 4, 2 and 3
DISC. OUT
Configure discrete outputs. For non-Wavestream units, these pins must be
connected; otherwise the unit will not be muted during transition.
SSPA-A/B
Lists submenus that may be accessed
Front Panel LEDS
Enable/disable the front panel LEDs.
TX On/Off
Enable/disable TX. This function is also available through the GUI.
Set Attenuation
Select value to increase or decrease the attenuation on the unit.
Save Unit Settings
After any changes, always SAVE the settings. Otherwise when the unit is power
cycled it will revert to the previously saved settings.
Unit Information
Provides the serial number and model number of the unit.
TX SW
Lists transmit switch selections.
Position A
Select and press Enter to set the TX switch to position A [1 and 2, 3 and 4].
Position B
Select and press Enter to set the TX switch to position B [1 and 4, 2 and 3].
RX SW
Lists receive switch selections.
Position A
Select and press Enter to set the RX switch to position A [1 and 2, 3 and 4].
Position B
Select and press Enter to set the RW switch to position B [1 and 4, 2 and 3].
DISC OUT
Sets (5 V) or clears (0 V) the discrete outputs on J2.
Output 0:
[
Clear/Set
]
Clear (0 V) this output
Set (5 V) this output
Output 1:
[
Clear/Set
]
Clear (0 V) this output
Set (5 V) this output
Output 2:
[
Clear/Set
] user defined
Clear (0 V) this output
Set (5 V) this output
Output 3:
[
Clear/Set
] user defined
Clear (0 V) this output
Set (5 V) this output