Redundancy Controller
Page
27
Document Number: 90-005-0030_E
GUI Description
Controls
Active control functions allowed from the GUI are shown as buttons. When a button is clicked the
command is sent to the unit. Dropdown menus are used to access local GUI functions.
Status
All digital monitor signal states have a description next to the name of the monitor. For example,
Summary Fault will display either Ok or Fault depending on the state.
Display readings
All analog monitor signal readings are presented in the appropriate units.
Tx Enable
Press to send a transmit enable signal to the unit. Transmitting is enabled if
there are no faults.
Tx Disable
Press to send a disable signal to the unit which will shut down the amplifier
unless the unit has been externally enabled.
Search Serial Ports
From the dropdown box select a communications port between the unit and the
controller.
Start
Select to start communications to the specified port. Once connected data will be
displayed.
Step Attenuation
Set the gain attenuator to a specific value. The value will be changed
immediately on the unit. The unit only holds from 0 to 20 dB of attenuation.
NOTE
:
Click
Save Settings
→ Save Attenuator Setting
to save the
state in non-volatile memory so that the unit will power up in this state.
The unit will revert to the saved value at power up.