Redundancy Controller
Page
22
Document Number: 90-005-0030_E
Redundancy
Select the redundancy that the units are configured for
1:1 simplex redundancy
[
OFF/ON
] Default is on.
If the primary unit goes into
summary fault mode, the RMC
automatically switches transmit to
the secondary unit. Rx is not
automatically switched.
1:1 duplex redundancy
[
OFF/ON
] Default is off. If the primary unit goes into summary fault mode, the
RMC automatically switches transmit and receive to the secondary unit.
RMC Front Panel Status and Control
Use the RMC front panel or the
GUI
to configure and control the RMC.
Power Up and Status
At power on the RMC displays the Monitor or Home display.
If SSPA unit A is connected correctly, the Summary status is displayed.
Press the right arrow to display the status of unit B.
Press the right arrow again to display the status of unit A.
Press the down arrow to step down, line by line through the status of the
SSPA-A or SSPA-B.
Pressing the up arrow steps the display back up through the status.
Status information includes:
If a unit is not connected,
FAULT
will be displayed when you press the
right arrow to display the status.
MON I T OR : K u 10 0 W A
S U MMA R Y : OK
T X : A C T I V E
R F F WD P OWE R : 4 8 . 5 d B m