WL2 FW
Manual
Page 71 – Revision EU05-07-17
14.
Place a pitcher, catch basin or other container under the faucet of the
WL2FW Water Treatment
System.
15.
Flush the Hot Tank until water runs clear.
16.
Once clear Water dispenses from the faucet the Hot Tank has been descaled. Always ensure the
WL2FW Water Treatment System
is performing to the customer’s satisfaction.
WARNING!
HOT WATER.
The
WL2FW Water Treatment System produces Hot Water up to
87°C (187°F).
Water above 52°C (125°F) can cause severe burns or scalding. Hot water should
be dispensed carefully into insulated container to avoid injury.
CAUTION
!
MUST REPLACE HOT TANK 3-5 YEARS DEPENDING ON USAGE
. The Hot Tank and
its controls must be replaced a minimum of every three to five years to ensure efficient and
dependable operation.
WARNING!
REINSTALL ALL PANELS AND COVERS.
Always reinstall all Panels, Protective
covers, and fasteners after servicing equipment. Failure to do so could result in severe
personal injury and will void the certifications and warranty of the equipment
.
Summary of Contents for WL2FL Free Standing
Page 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Page 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Page 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Page 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Page 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Page 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Page 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...