WL2 FW
Manual
Page 61 – Revision EU05-07-17
7.
Restricted Flow of Hot Water
Possible Reason
Solution
Partially closed water supply valve to
the unit.
Open water supply valve.
Hot Tank outlet hole is scaled over.
Descale Tank.
See Hot Tank Descaling Instructions that are included
further below in this Troubleshooting Section.
See instructional video on the Partner Area of the
Waterlogic.com website for more information.
See instructional video on the Partner Area of the
Waterlogic.com website for more information.
Tubing is creased or has a “kink” in it.
Inspect and replace tubing as necessary.
Faucet nipple screen mesh has
obstruction(s)
Unscrew faucet nipple from faucet and remove any
obstruction(s) from screen mesh.
Exhausted Filter
Replace the Filter
Solenoid connection to the Display
PCB
Turn power off; unplug the
WL2FW Water Treatment
System
and visually inspect solenoid connections into the
Display PCB. Verify the soldering points on connections are
secure into the board.
Remove the PCB to inspect the front of the board.
Solenoid Valve is Malfunctioning
Inspect valve components for proper function. Replace as
necessary.
Summary of Contents for WL2FL Free Standing
Page 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Page 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Page 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Page 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Page 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Page 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Page 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...